Potentiometric Endress Hauser PH ORP Transmitter Liquisys CPM253-PR0510

Brand Name: Endress Hauser
Model Number: CPM253-PR0510
MOQ: 1
Price: Negotiable
Delivery Time: Negotiable
Payment Terms: T/T
Detail Information
Place of Origin:
Germany
Certification:
ATEX
Measuring Principle:
Potentiometric
Characteristic:
4-wire Transmitter
Ingress Protection:
No
Ex Certification:
No
Temperature Sensor:
Display And Current Output
Material:
PC/ABS Housing
Packaging Details:
carton
Supply Ability:
100pcs per month
Highlight:

Potentiometric ph orp transmitter

,

ABS housing Liquisys CPM253

,

cpm253 endress hauser

Product Description

Endress Hauser pH/ORP transmitterLiquisys CPM253-PR0510

Field of application

Liquisys CPM253 is a standard pH/ORP transmitter for all analog and digital Memosens sensors. It improves your operational safety thanks to continuous plausibility, process and sensor checks. Select from numerous hardware and software modules, such as relays or fieldbus communication, to adapt it exactly to your measuring task. This modularity also allows you to upgrade the transmitter at any time. A simple menu and two-point calibration make configuration and operation fast and easy.

 

The Liquisys CPM253 transmitter works with all pH/ORP glass and ISFET sensors in non-hazardous areas, for example in these industries and their utilities:

  • Chemicals

  • Food & Beverages

  • Power & Energy

  • Water & Wastewater

  • Primaries & Metal

Liquisys CPM253 features the following protocols and interfaces:

  • 0/4...20 mA

  • HART

  • PROFIBUS DP

  • PROFIBUS PA

  •  

Potentiometric

 

Measuring principle

Potentiometric

 

Application

Water, waste water, process

 

Characteristic

4-wire transmitter

 

Design

pH/ORP field housing made of PC/ABS

 

Material

PC/ABS housing

 

Dimension

247x170x115mm

(9.63x6.63x4.48inch)

 

Temperature sensor

Display and current output

 

Ex certification

No

 

Ingress protection

No

 

Input

One-channel-transmitter

 

Output / communication

0/4-20 mA, Hart, Profibus

 

Additional certifications

CSA Gen. purpose

Potentiometric Endress Hauser PH ORP Transmitter Liquisys CPM253-PR0510 0

Potentiometric Endress Hauser PH ORP Transmitter Liquisys CPM253-PR0510 1

 

Measured variables pH (analog or digital sensors) ORP Temperature
   
Measuring range pH: –2 to 16 ORP: –1500 to +1500 mV / 0 to 100 % Temperature: Pt 100 -50 to +150 °C (-58 to +302 °F) Pt 1000 (versions IS / PS) -50 to +150 °C (-58 to +302 °F) NTC 30K (versions IS / PS) -20 to +100 °C (-4 to +212 °F)
Input resistance > 1012  (for nominal operating conditions) for standard sensors

 

Good price  online

Products Details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Endress Hauser Instruments
Created with Pixso. Potentiometric Endress Hauser PH ORP Transmitter Liquisys CPM253-PR0510

Potentiometric Endress Hauser PH ORP Transmitter Liquisys CPM253-PR0510

Brand Name: Endress Hauser
Model Number: CPM253-PR0510
MOQ: 1
Price: Negotiable
Packaging Details: carton
Payment Terms: T/T
Detail Information
Place of Origin:
Germany
Brand Name:
Endress Hauser
Certification:
ATEX
Model Number:
CPM253-PR0510
Measuring Principle:
Potentiometric
Characteristic:
4-wire Transmitter
Ingress Protection:
No
Ex Certification:
No
Temperature Sensor:
Display And Current Output
Material:
PC/ABS Housing
Minimum Order Quantity:
1
Price:
Negotiable
Packaging Details:
carton
Delivery Time:
Negotiable
Payment Terms:
T/T
Supply Ability:
100pcs per month
Highlight:

Potentiometric ph orp transmitter

,

ABS housing Liquisys CPM253

,

cpm253 endress hauser

Product Description

Endress Hauser pH/ORP transmitterLiquisys CPM253-PR0510

Field of application

Liquisys CPM253 is a standard pH/ORP transmitter for all analog and digital Memosens sensors. It improves your operational safety thanks to continuous plausibility, process and sensor checks. Select from numerous hardware and software modules, such as relays or fieldbus communication, to adapt it exactly to your measuring task. This modularity also allows you to upgrade the transmitter at any time. A simple menu and two-point calibration make configuration and operation fast and easy.

 

The Liquisys CPM253 transmitter works with all pH/ORP glass and ISFET sensors in non-hazardous areas, for example in these industries and their utilities:

  • Chemicals

  • Food & Beverages

  • Power & Energy

  • Water & Wastewater

  • Primaries & Metal

Liquisys CPM253 features the following protocols and interfaces:

  • 0/4...20 mA

  • HART

  • PROFIBUS DP

  • PROFIBUS PA

  •  

Potentiometric

 

Measuring principle

Potentiometric

 

Application

Water, waste water, process

 

Characteristic

4-wire transmitter

 

Design

pH/ORP field housing made of PC/ABS

 

Material

PC/ABS housing

 

Dimension

247x170x115mm

(9.63x6.63x4.48inch)

 

Temperature sensor

Display and current output

 

Ex certification

No

 

Ingress protection

No

 

Input

One-channel-transmitter

 

Output / communication

0/4-20 mA, Hart, Profibus

 

Additional certifications

CSA Gen. purpose

Potentiometric Endress Hauser PH ORP Transmitter Liquisys CPM253-PR0510 0

Potentiometric Endress Hauser PH ORP Transmitter Liquisys CPM253-PR0510 1

 

Measured variables pH (analog or digital sensors) ORP Temperature
   
Measuring range pH: –2 to 16 ORP: –1500 to +1500 mV / 0 to 100 % Temperature: Pt 100 -50 to +150 °C (-58 to +302 °F) Pt 1000 (versions IS / PS) -50 to +150 °C (-58 to +302 °F) NTC 30K (versions IS / PS) -20 to +100 °C (-4 to +212 °F)
Input resistance > 1012  (for nominal operating conditions) for standard sensors