Brand Name: | IFM |
Model Number: | TM4811 |
MOQ: | 1 |
Price: | Negotiable |
Delivery Time: | Negotiable |
Payment Terms: | T/T |
IFM Temperature sensor with process connection TM4811 TM-050KFEC01- /US/
Precise temperature measurement in containers, tanks and pipes
For the connection to an evaluation unit
Very short response time for use in processes with fast temperature fluctuations
Hygienic design for the requirements of the food and beverage industry
Variable process connection using adapters
Measuring range | -40...150 °C-40...302 °F |
Process connection | Clamp DN25...DN40 (1...1,5") DIN 32676 (ISO 2852) |
Installation length EL[mm] | 50 |
System | gold-plated contacts |
Measuring element | 1 x Pt 100; (to DIN EN 60751, class A) |
Application | hygienic systems |
Media | liquids and gases |
Pressure rating | 25 bar2.5 MPa |
Minimum installation depth[mm] | 15 |
MAWP (for applications according to CRN)[bar] | 50 |
Protection class | III |
Probe length L[mm] | 50 |
Measuring range | -40...150 °C-40...302 °F |
Accuracy[K] | ± (0,15 K + 0,002 x|t|) |
Dynamic response T05 / T09[s] | 1 / 3; (according to DIN EN 60751) |
Ambient temperature[°C] | -25...80 |
Storage temperature[°C] | -40...100 |
Protection | IP 68; IP 69K |
Shock resistance | DIN EN 60068-2-2-2750 g (11 ms) |
Vibration resistance | DIN EN 60068-2-610 g (10...2000 Hz) |
MTTF[years] | 22831 |
Weight[g] | 184 |
Housing | tubular |
Dimensions[mm] | Ø 49.8 / L = 74 |
Material | stainless steel (1.4404 / 316L) |
Materials (wetted parts) | stainless steel (1.4404 / 316L) electropolished |
Process connection | Clamp DN25...DN40 (1...1,5") DIN 32676 (ISO 2852) |
Surface characteristics Ra/Rz of the wetted parts | Ra: < 0.8 |
Probe diameter[mm] | 6 |
Installation length EL[mm] | 50 |
Remarks | cULus - Class 2 source requiredThe values for accuracy apply to flowing water. |
Pack quantity | 1 pcs. |
Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |
Brand Name: | IFM |
Model Number: | TM4811 |
MOQ: | 1 |
Price: | Negotiable |
Packaging Details: | carton |
Payment Terms: | T/T |
IFM Temperature sensor with process connection TM4811 TM-050KFEC01- /US/
Precise temperature measurement in containers, tanks and pipes
For the connection to an evaluation unit
Very short response time for use in processes with fast temperature fluctuations
Hygienic design for the requirements of the food and beverage industry
Variable process connection using adapters
Measuring range | -40...150 °C-40...302 °F |
Process connection | Clamp DN25...DN40 (1...1,5") DIN 32676 (ISO 2852) |
Installation length EL[mm] | 50 |
System | gold-plated contacts |
Measuring element | 1 x Pt 100; (to DIN EN 60751, class A) |
Application | hygienic systems |
Media | liquids and gases |
Pressure rating | 25 bar2.5 MPa |
Minimum installation depth[mm] | 15 |
MAWP (for applications according to CRN)[bar] | 50 |
Protection class | III |
Probe length L[mm] | 50 |
Measuring range | -40...150 °C-40...302 °F |
Accuracy[K] | ± (0,15 K + 0,002 x|t|) |
Dynamic response T05 / T09[s] | 1 / 3; (according to DIN EN 60751) |
Ambient temperature[°C] | -25...80 |
Storage temperature[°C] | -40...100 |
Protection | IP 68; IP 69K |
Shock resistance | DIN EN 60068-2-2-2750 g (11 ms) |
Vibration resistance | DIN EN 60068-2-610 g (10...2000 Hz) |
MTTF[years] | 22831 |
Weight[g] | 184 |
Housing | tubular |
Dimensions[mm] | Ø 49.8 / L = 74 |
Material | stainless steel (1.4404 / 316L) |
Materials (wetted parts) | stainless steel (1.4404 / 316L) electropolished |
Process connection | Clamp DN25...DN40 (1...1,5") DIN 32676 (ISO 2852) |
Surface characteristics Ra/Rz of the wetted parts | Ra: < 0.8 |
Probe diameter[mm] | 6 |
Installation length EL[mm] | 50 |
Remarks | cULus - Class 2 source requiredThe values for accuracy apply to flowing water. |
Pack quantity | 1 pcs. |
Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |