logo
Good price  online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
MTL Instruments
Created with Pixso. MTL4541 MTL Instruments Repeater Power Supply

MTL4541 MTL Instruments Repeater Power Supply

Brand Name: MTL
Model Number: MTL4541
MOQ: 1
Price: Negotiate
Delivery Time: stock
Payment Terms: T/T
Detail Information
Place of Origin:
UK/China
Certification:
HART
Manufacturer:
MTL Instruments
Product No:
MTL4541
Signal Range:
4 To 20mA
Under/over-range:
0 To 24mA
Shipping Weight:
1kg
Quality Guarantee:
1 Year
Safe-area Circuit Output Resistance:
> 1MO
Temperature Drift:
< 0.8µA/°C
Packaging Details:
carton
Supply Ability:
1000pcs per week
Product Description

MTL4541  MTL Instruments Repeater Power Supply

        MTLx541 provides a fully-floating dc supply for energising a conventional 2- or 3-wire 4/20mA transmitter, which is located in a hazardous area, and repeats the current in another floating circuit to drive a safe-area load. For HART 2-wire transmitters, the unit allows bi-directional communications signals superimposed on the 4/20mA loop current. Alternatively, the MTLx541S acts as a current sink for a safe-area connection rather than driving a current into the load. Separately powered current sources, such as 4-wire transmitters, can be connected but will not support HART communication.16ch AIO 4-20mA


REPEATER POWER SUPPLY

4/20mA, HART®, 2- or 3-wire transmitters

Number of channels : One

Location of transmitter : Zone 0, IIC, T4–6 hazardous area if suitably certified, Div. 1, Group A hazardous location

Safe-area output

Signal range: 4 to 20mA

Under/over-range: 0 to 24mA

Safe-area load resistance (MTLx541) : @ 24mA: 0 to 360Ω @ 20mA: 0 to 450Ω

Safe-area load (MTLx541S) : Current sink: 600Ω max.

Maximum voltage source: 24V dc

Safe-area circuit output resistance: > 1MΩ

Safe-area circuit ripple : < 50μA peak-to-peak

Hazardous-area input : Signal range: 0 to 24mA (including over-range), Transmitter voltage: 16.5V at 20mA

Transfer accuracy at 20°C : Better than 15μA

Temperature drift : < 0.8μA/°C

Response time : Settles to within 10% of final value within 50μs

Communications supported : HART (terminals 1 & 2 only)

LED indicator : Green: power indication

Maximum current consumption (with 20mA signal) : 51mA at 24V

Power dissipation within unit (with 20mA signal) : MTLx541 0.7W @ 24V dc, MTLx541S 1.0W @ 24V dc

MTL4541  MTL Instruments Repeater Power Supply 0



Good price  online

Products Details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
MTL Instruments
Created with Pixso. MTL4541 MTL Instruments Repeater Power Supply

MTL4541 MTL Instruments Repeater Power Supply

Brand Name: MTL
Model Number: MTL4541
MOQ: 1
Price: Negotiate
Packaging Details: carton
Payment Terms: T/T
Detail Information
Place of Origin:
UK/China
Brand Name:
MTL
Certification:
HART
Model Number:
MTL4541
Manufacturer:
MTL Instruments
Product No:
MTL4541
Signal Range:
4 To 20mA
Under/over-range:
0 To 24mA
Shipping Weight:
1kg
Quality Guarantee:
1 Year
Safe-area Circuit Output Resistance:
> 1MO
Temperature Drift:
< 0.8µA/°C
Minimum Order Quantity:
1
Price:
Negotiate
Packaging Details:
carton
Delivery Time:
stock
Payment Terms:
T/T
Supply Ability:
1000pcs per week
Product Description

MTL4541  MTL Instruments Repeater Power Supply

        MTLx541 provides a fully-floating dc supply for energising a conventional 2- or 3-wire 4/20mA transmitter, which is located in a hazardous area, and repeats the current in another floating circuit to drive a safe-area load. For HART 2-wire transmitters, the unit allows bi-directional communications signals superimposed on the 4/20mA loop current. Alternatively, the MTLx541S acts as a current sink for a safe-area connection rather than driving a current into the load. Separately powered current sources, such as 4-wire transmitters, can be connected but will not support HART communication.16ch AIO 4-20mA


REPEATER POWER SUPPLY

4/20mA, HART®, 2- or 3-wire transmitters

Number of channels : One

Location of transmitter : Zone 0, IIC, T4–6 hazardous area if suitably certified, Div. 1, Group A hazardous location

Safe-area output

Signal range: 4 to 20mA

Under/over-range: 0 to 24mA

Safe-area load resistance (MTLx541) : @ 24mA: 0 to 360Ω @ 20mA: 0 to 450Ω

Safe-area load (MTLx541S) : Current sink: 600Ω max.

Maximum voltage source: 24V dc

Safe-area circuit output resistance: > 1MΩ

Safe-area circuit ripple : < 50μA peak-to-peak

Hazardous-area input : Signal range: 0 to 24mA (including over-range), Transmitter voltage: 16.5V at 20mA

Transfer accuracy at 20°C : Better than 15μA

Temperature drift : < 0.8μA/°C

Response time : Settles to within 10% of final value within 50μs

Communications supported : HART (terminals 1 & 2 only)

LED indicator : Green: power indication

Maximum current consumption (with 20mA signal) : 51mA at 24V

Power dissipation within unit (with 20mA signal) : MTLx541 0.7W @ 24V dc, MTLx541S 1.0W @ 24V dc

MTL4541  MTL Instruments Repeater Power Supply 0