Brand Name: | IFM |
Model Number: | TA2435 |
MOQ: | 1 |
Price: | Negotiable |
Delivery Time: | Negotiable |
Payment Terms: | T/T |
IFM Temperature transmitter TA2435 TA-100CLER12-A-ZVG/US
High precision across the entire temperature measurement range
Fast response dynamics and very short power-on delay time
Robust stainless steel housing with high pressure resistance
High protection rating for the requirements of harsh industrial environments
Number of inputs and outputs | Number of analog outputs: 1 |
Measuring range[°C] | -50...150 |
Communication interface | IO-Link |
Process connection | threaded connection G 1/2 external thread |
Installation length EL[mm] | 100 |
System | gold-plated contacts |
Measuring element | 1 x Pt 1000; (to DIN EN 60751, class A) |
Media | liquids and gases |
Pressure rating | 300 bar30 MPa |
Note on pressure rating | sensorWhen mounted in adapters the specifications of the adapter data sheet apply. |
Operating voltage[V] | 18...32 DC; (cULus - Class 2 source required) |
Current consumption[mA] | < 50 |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time[s] | 1 |
Number of inputs and outputs | Number of analog outputs: 1 |
Total number of outputs | 1 |
Output signal | analog signal; IO-Link; (configurable) |
Number of analog outputs | 1 |
Analog current output[mA] | 4...20 |
Max. load[Ω] | 250; ((18...19 V); 19...32 V: 300 Ω) |
Short-circuit protection | yes |
Overload protection | yes |
Probe length L[mm] | 86 |
Measuring range[°C] | -50...150 |
Factory setting | -50...150 °C |
Precision analog output[K] | ± 0,3 + (± 0,1 % MS) |
Temperature coefficient[% of the span / 10 K] | 0,1; (In case of deviation from the reference condition 25 ± 5 °C) |
Dynamic response T05 / T09[s] | 1 / 3 |
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
Ambient temperature[°C] | -25...80 |
Storage temperature[°C] | -40...100 |
Protection | IP 67; IP 68; IP 69K |
EMC | DIN EN 61000-6-2 |
Shock resistance | DIN IEC 68-2-2750 g (11 ms) |
Vibration resistance | DIN IEC 68-2-620 g (10...2000 Hz) |
MTTF[years] | 572 |
UL approval | UL approval numberK002 |
Weight[g] | 134.5 |
Housing | tubular |
Dimensions[mm] | Ø 18.7 / L = 163.9 |
Material | stainless steel (1.4404 / 316L); PEI; FKM |
Materials (wetted parts) | stainless steel (1.4404 / 316L); O-ring: FKM |
Tightening torque[Nm] | 45 |
Process connection | threaded connection G 1/2 external thread |
Probe diameter[mm] | 6 |
Installation length EL[mm] | 100 |
![]() |
Brand Name: | IFM |
Model Number: | TA2435 |
MOQ: | 1 |
Price: | Negotiable |
Packaging Details: | carton |
Payment Terms: | T/T |
IFM Temperature transmitter TA2435 TA-100CLER12-A-ZVG/US
High precision across the entire temperature measurement range
Fast response dynamics and very short power-on delay time
Robust stainless steel housing with high pressure resistance
High protection rating for the requirements of harsh industrial environments
Number of inputs and outputs | Number of analog outputs: 1 |
Measuring range[°C] | -50...150 |
Communication interface | IO-Link |
Process connection | threaded connection G 1/2 external thread |
Installation length EL[mm] | 100 |
System | gold-plated contacts |
Measuring element | 1 x Pt 1000; (to DIN EN 60751, class A) |
Media | liquids and gases |
Pressure rating | 300 bar30 MPa |
Note on pressure rating | sensorWhen mounted in adapters the specifications of the adapter data sheet apply. |
Operating voltage[V] | 18...32 DC; (cULus - Class 2 source required) |
Current consumption[mA] | < 50 |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time[s] | 1 |
Number of inputs and outputs | Number of analog outputs: 1 |
Total number of outputs | 1 |
Output signal | analog signal; IO-Link; (configurable) |
Number of analog outputs | 1 |
Analog current output[mA] | 4...20 |
Max. load[Ω] | 250; ((18...19 V); 19...32 V: 300 Ω) |
Short-circuit protection | yes |
Overload protection | yes |
Probe length L[mm] | 86 |
Measuring range[°C] | -50...150 |
Factory setting | -50...150 °C |
Precision analog output[K] | ± 0,3 + (± 0,1 % MS) |
Temperature coefficient[% of the span / 10 K] | 0,1; (In case of deviation from the reference condition 25 ± 5 °C) |
Dynamic response T05 / T09[s] | 1 / 3 |
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
Ambient temperature[°C] | -25...80 |
Storage temperature[°C] | -40...100 |
Protection | IP 67; IP 68; IP 69K |
EMC | DIN EN 61000-6-2 |
Shock resistance | DIN IEC 68-2-2750 g (11 ms) |
Vibration resistance | DIN IEC 68-2-620 g (10...2000 Hz) |
MTTF[years] | 572 |
UL approval | UL approval numberK002 |
Weight[g] | 134.5 |
Housing | tubular |
Dimensions[mm] | Ø 18.7 / L = 163.9 |
Material | stainless steel (1.4404 / 316L); PEI; FKM |
Materials (wetted parts) | stainless steel (1.4404 / 316L); O-ring: FKM |
Tightening torque[Nm] | 45 |
Process connection | threaded connection G 1/2 external thread |
Probe diameter[mm] | 6 |
Installation length EL[mm] | 100 |
![]() |