MTL5514 MTL Switch/Proximity Detector Interface Response time 10ms maximum
The MTLx514 enables a safe–area load to be controlled, through a relay, by a proximity detector or switch located in a hazardous area. Line faults
are signalled through a separate relay and indicated on the top of the module. Switches are provided to select phase reversal and to enable the line fault detection
Number of channels
One
Location of switch
Zone 0, IIC, T6 hazardous area
Div.1, Group A, hazardous location
Location of proximity detector
Zone 0, IIC, T4–6 hazardous area, if suitably certified
Div.1, Group A, hazardous location
Hazardous–area inputs
Inputs conforming to BS EN60947–5–6:2001 standards for
proximity detectors (NAMUR)
Voltage applied to sensor
7 to 9V dc from 1kΩ ±10%
Input/output characteristics
Normal phase
Outputs closed if input > 2.1mA (< 2kΩ in input circuit)
Outputs open if input < 1.2mA (> 10kΩ in input circuit)
Hysteresis: 200µA (650Ω) nominal
Line fault detection (LFD) (when selected)
User-selectable via switches on the side of the unit. Line faults
are indicated by an LED. Line fault relay is energised and channel
output relay de-energised if input line-fault detected
Open-circuit alarm on if Iin < 50µA
Open-circuit alarm off if Iin > 250µA
Short-circuit alarm on if Rin < 100Ω
Short-circuit alarm off if Rin > 360Ω
Note: Resistors must be fitted when using the LFD facility with a contact input
500Ω to 1kΩ in series with switch
20kΩ to 25kΩ in parallel with switch
Safe-area output
Channel: Single pole relay with changeover contacts
LFD: Single pole relay with changeover contacts
Note: reactive loads must be adequately suppressed
HCU16 | MTL5521 | MTL4575 |
HCU3700 | MTL5522 | MTL4646Y |
HM64RIB20-1.0 | MTL5531 | MTL4850 |
HM64RIB20-1.5 | MTL5532 | MTL4851 |
HMM64 | MTL5541 | MTL4852 |
HMRIB16-1.0 | MTL5541S | MTL5018 |
HMS64 | MTL5544 | MTL5032 |
HTP-SC32 | MTL5544D | MTL5042 |
MTL4044D | MTL5546 | MTL5044 |
MTL4511 | MTL5546Y | MTL5049 |
MTL4516 | MTL5561 | MTL5511 |
MTL4516C | MTL5573 | MTL5514D |
MTL4521 | MTL5575 | MTL5516 |
MTL4541 | MTL5582B | MTL5516C |
MTL4541 | MTL7728+ | MTL7787P+ |
MTL4544 | MTL7756AC | MTLCPS16 |
MTL4544D | MTL7760AC | NJ5-18GK-N |
MTL4546Y | MTL7761PAC | SD150X |
MTL4549Y | MTL7765AC | SD32 |
MTL4573 | MTL7787+ | SD32X |
TP48-4-N-NDI | TP48-3-N-NDI | SDRTD |
TP48-N-NDI | TP48-4-I-NDI | SLP32D |
Brand Name: | MTL |
Model Number: | MTL5514 |
MOQ: | 1 |
Price: | Negotiate |
Packaging Details: | carton |
Payment Terms: | T/T |
MTL5514 MTL Switch/Proximity Detector Interface Response time 10ms maximum
The MTLx514 enables a safe–area load to be controlled, through a relay, by a proximity detector or switch located in a hazardous area. Line faults
are signalled through a separate relay and indicated on the top of the module. Switches are provided to select phase reversal and to enable the line fault detection
Number of channels
One
Location of switch
Zone 0, IIC, T6 hazardous area
Div.1, Group A, hazardous location
Location of proximity detector
Zone 0, IIC, T4–6 hazardous area, if suitably certified
Div.1, Group A, hazardous location
Hazardous–area inputs
Inputs conforming to BS EN60947–5–6:2001 standards for
proximity detectors (NAMUR)
Voltage applied to sensor
7 to 9V dc from 1kΩ ±10%
Input/output characteristics
Normal phase
Outputs closed if input > 2.1mA (< 2kΩ in input circuit)
Outputs open if input < 1.2mA (> 10kΩ in input circuit)
Hysteresis: 200µA (650Ω) nominal
Line fault detection (LFD) (when selected)
User-selectable via switches on the side of the unit. Line faults
are indicated by an LED. Line fault relay is energised and channel
output relay de-energised if input line-fault detected
Open-circuit alarm on if Iin < 50µA
Open-circuit alarm off if Iin > 250µA
Short-circuit alarm on if Rin < 100Ω
Short-circuit alarm off if Rin > 360Ω
Note: Resistors must be fitted when using the LFD facility with a contact input
500Ω to 1kΩ in series with switch
20kΩ to 25kΩ in parallel with switch
Safe-area output
Channel: Single pole relay with changeover contacts
LFD: Single pole relay with changeover contacts
Note: reactive loads must be adequately suppressed
HCU16 | MTL5521 | MTL4575 |
HCU3700 | MTL5522 | MTL4646Y |
HM64RIB20-1.0 | MTL5531 | MTL4850 |
HM64RIB20-1.5 | MTL5532 | MTL4851 |
HMM64 | MTL5541 | MTL4852 |
HMRIB16-1.0 | MTL5541S | MTL5018 |
HMS64 | MTL5544 | MTL5032 |
HTP-SC32 | MTL5544D | MTL5042 |
MTL4044D | MTL5546 | MTL5044 |
MTL4511 | MTL5546Y | MTL5049 |
MTL4516 | MTL5561 | MTL5511 |
MTL4516C | MTL5573 | MTL5514D |
MTL4521 | MTL5575 | MTL5516 |
MTL4541 | MTL5582B | MTL5516C |
MTL4541 | MTL7728+ | MTL7787P+ |
MTL4544 | MTL7756AC | MTLCPS16 |
MTL4544D | MTL7760AC | NJ5-18GK-N |
MTL4546Y | MTL7761PAC | SD150X |
MTL4549Y | MTL7765AC | SD32 |
MTL4573 | MTL7787+ | SD32X |
TP48-4-N-NDI | TP48-3-N-NDI | SDRTD |
TP48-N-NDI | TP48-4-I-NDI | SLP32D |