logo
Good price  online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Pepperl Fuchs Safety Barrier
Created with Pixso. 12V Pepperl Fuchs LB5105A Module Thermocouple Converter 0.75W

12V Pepperl Fuchs LB5105A Module Thermocouple Converter 0.75W

Brand Name: PEPPERL FUCHS
Model Number: LB5105A
MOQ: 1
Price: Negotiable
Delivery Time: Negotiable
Payment Terms: T/T
Detail Information
Place of Origin:
Germany
Manufacturer:
PEPPERL FUCHS
Product No:
LB5105A
Connection:
Backplane Bus
Power Dissipation:
0.75 W
Linearity Error:
0.1 %
Relative Humidity:
95 % Non-condensing
Altitude:
Max. 2000 M
Packaging Details:
carton
Supply Ability:
100pcs per month
Highlight:

Pepperl Fuchs Thermocouple Converter

,

Thermocouple Converter 0.75W

,

LB5105A Module

Product Description

Pepperl+Fuchs LB5105A Module Thermocouple Converter with Backplane Bus Connection and 0.75 W Power Dissipation

 

Slots
Occupied slots    2
Supply
Connection    backplane bus
Rated voltage    12 V DC , only in connection with the power supplies LB9***
Power dissipation    0.75 W
Power consumption    0.75 W
Internal bus
Connection    backplane bus
Interface    manufacturer-specific bus to standard com unit
Input
Compensation (reference junction CJC)    internal cold junction compensation or external cold junction
temperature input
Number of channels    4
Suitable field devices    
Field device [2]    Thermocouple
Field device [4]    mV source
Suitable sensors    
Sensor    thermocouples U, B, E, T, K, S, R, L, J, N, Pallaplat and mV sources
Connection    channel I: 1+, 2-; channel II: 5+, 6-; channel III: 9+, 10-; channel IV: 13+, 14-
Measuring range    -65 ... 75 mV with LFD , -75 ... 75 mV without LFD
Smallest span    5 mV for 0.1 % accuracy
Linearity error    0.1 %
Conversion time    max. 300 ms (4 channels) without LFD max. 600 ms (4-channel) with LFD
Compensation (reference junction CJC)    internal cold junction compensation or external cold junction
Line fault detection    can be switched on/off for each channel via configuration tool ,
Open-circuit    > 1 kΩ
Transfer characteristics
Deviation    
Influence of ambient temperature    max. 0,1 %/10 K
Indicators/settings
LED indication    Power LED (P) green: supply
Status LED (I) red: line fault (collective alarm) , red flashing: communication error
Coding    optional mechanical coding via front socket
Directive conformity
Electromagnetic compatibility    
Directive 2014/30/EU    EN 61326-1:2013

 

12V  Pepperl Fuchs LB5105A Module Thermocouple Converter 0.75W 0

 

Good price  online

Products Details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Pepperl Fuchs Safety Barrier
Created with Pixso. 12V Pepperl Fuchs LB5105A Module Thermocouple Converter 0.75W

12V Pepperl Fuchs LB5105A Module Thermocouple Converter 0.75W

Brand Name: PEPPERL FUCHS
Model Number: LB5105A
MOQ: 1
Price: Negotiable
Packaging Details: carton
Payment Terms: T/T
Detail Information
Place of Origin:
Germany
Brand Name:
PEPPERL FUCHS
Model Number:
LB5105A
Manufacturer:
PEPPERL FUCHS
Product No:
LB5105A
Connection:
Backplane Bus
Power Dissipation:
0.75 W
Linearity Error:
0.1 %
Relative Humidity:
95 % Non-condensing
Altitude:
Max. 2000 M
Minimum Order Quantity:
1
Price:
Negotiable
Packaging Details:
carton
Delivery Time:
Negotiable
Payment Terms:
T/T
Supply Ability:
100pcs per month
Highlight:

Pepperl Fuchs Thermocouple Converter

,

Thermocouple Converter 0.75W

,

LB5105A Module

Product Description

Pepperl+Fuchs LB5105A Module Thermocouple Converter with Backplane Bus Connection and 0.75 W Power Dissipation

 

Slots
Occupied slots    2
Supply
Connection    backplane bus
Rated voltage    12 V DC , only in connection with the power supplies LB9***
Power dissipation    0.75 W
Power consumption    0.75 W
Internal bus
Connection    backplane bus
Interface    manufacturer-specific bus to standard com unit
Input
Compensation (reference junction CJC)    internal cold junction compensation or external cold junction
temperature input
Number of channels    4
Suitable field devices    
Field device [2]    Thermocouple
Field device [4]    mV source
Suitable sensors    
Sensor    thermocouples U, B, E, T, K, S, R, L, J, N, Pallaplat and mV sources
Connection    channel I: 1+, 2-; channel II: 5+, 6-; channel III: 9+, 10-; channel IV: 13+, 14-
Measuring range    -65 ... 75 mV with LFD , -75 ... 75 mV without LFD
Smallest span    5 mV for 0.1 % accuracy
Linearity error    0.1 %
Conversion time    max. 300 ms (4 channels) without LFD max. 600 ms (4-channel) with LFD
Compensation (reference junction CJC)    internal cold junction compensation or external cold junction
Line fault detection    can be switched on/off for each channel via configuration tool ,
Open-circuit    > 1 kΩ
Transfer characteristics
Deviation    
Influence of ambient temperature    max. 0,1 %/10 K
Indicators/settings
LED indication    Power LED (P) green: supply
Status LED (I) red: line fault (collective alarm) , red flashing: communication error
Coding    optional mechanical coding via front socket
Directive conformity
Electromagnetic compatibility    
Directive 2014/30/EU    EN 61326-1:2013

 